Description
The testo 760-2 instrument is a versatile tool for all important electrical measurement tasks. Thanks to automatic parameter detection, it ensures the highest reliability for any application. With this instrument, you can also measure current in the µA range and be confident in its accuracy thanks to the True Root Mean Square measurement function.
The testo 760-2 allows you to measure electrical parameters easier and faster than before. Unlike other instruments, the testo 760-2 automatically detects the relevant measuring parameter by recognizing the connected probe’s jack, which eliminates any hazardous incorrect settings.
The instrument is operated using backlit function buttons rather than a rotary switch. This allows you to easily control the measuring instrument with just one hand. The large backlit display clearly shows the readings.
The testo 760-2 possesses the most important functions for measuring current, voltage, and resistance. Current measurement can also be performed in the µA range thanks to the larger measuring range.
The integrated low-pass filter allows for more accurate measurement results on frequency-controlled motors.
In addition to electrical parameters, this instrument can also measure temperature.
Technical Data (Order Number 0590 7602)
General Technical Data
| Weight: | 340 g |
| Dimensions: | 167 x 85 x 45 mm |
| Housing Color: | black |
| Operating Temperature: | -10 … +50 °C |
| Storage Temperature: | -15 … +60 °C |
| Operating Humidity: | 0 … 80 % RH |
| Protection Class: | IP64 |
| Standards: | EN 61326-1; EN 61010-2-033; EN 61140 |
| Overvoltage Category: | CAT III 1000V; CAT IV 600V |
| Battery Type: | 3 AAA batteries |
| Display Type: | LCD |
| Display Size: | two lines |
| Interface: | 4 measuring jacks |
| High-pass filter: | yes |
| Display (Resolution): | 6 000 |
Temperature Measurement (Type K Thermocouple)
| Measuring Range: | -20 … +500 °C |
| Resolution: | 0.2 °C |
| Accuracy (0 … +100 °C): | ±1 °C |
DC Voltage
| Measuring range: | 0.1 … 600 V |
| Resolution: | max. 0.1 meas. value |
| Accuracy: | ± (0.8 % of meas. value + 3 Digit) |
AC Voltage
| Measuring range: | 0.1 meas. value … 600 V |
| Resolution: | max. 0.1 meas. value |
| Accuracy: | ± (1.0 % of meas. value + 3 Digit) |
DC Current
| Measuring range: | 0.1 µA … 10 A |
| Resolution: | max. 0.1 |
| Accuracy: | ± (1.5 % of meas. value + 5 Digit) |
AC Current
| Measuring range: | 0.1 µA … 10 A |
| Resolution: | max. 0.1 µA |
| Accuracy: | ± (1.5 % of meas. value + 5 Digit) |
Resistance
| Measuring range: | 0.01 … 60.00 MΩ |
| Resolution: | max. 0.01 Ω |
| Accuracy: | ± (1.5 % of meas. value + 3 Digit) |
Capacitance
| Measuring range: | 2 nF … 30.00 mF |
| Resolution: | max. 0.01 nF |
| Accuracy: | ± (1.5 % of meas. value + 5 Digit) |
Frequency
| Measuring range: | 2 Hz … 60.00 MHz |
| Resolution: | max. 0.1 Hz |
| Accuracy: | ± (0.1 % of meas. value + 1 Digit) |