Description
CFR pressure data logger testo 190-P1: Qualification of Sterilization and Lyophilization Processes
The reliable and robust testo 190-P1 CFR pressure data logger is designed for effectively meeting the stringent requirements for the qualification and validation of **sterilization** and **freeze-drying (lyophilization)** processes in the pharmaceutical industry. It is used for monitoring absolute pressure.Advantages and Design Features of the testo 190-P1 CFR Logger
- High Accuracy: The data logger has a memory capacity of 60,000 measured values.
- Compact and Slim: The logger’s diameter is 20 mm, making it ideal for confined spaces, such as recesses in lyophilization systems.
- Robust and Reliable: The measuring ‘core’ is encased in a separate stainless steel housing, which ensures exceptional durability and protection against external influences.
- Instant Battery Replacement: Thanks to the screw-in design, the battery can be replaced quickly and safely without special tools.
- Hermetic Sealing: The logger remains completely hermetically sealed even after battery replacement. The battery housing is covered with temperature-resistant Polyetheretherketone (PEEK).
- Variable Height: The size of the logger can be changed depending on the use of one of **two battery types**. The large battery (included) is suitable for measuring low temperatures.
Programming, Readout, and Data Analysis
- Multi-functional Case: The case (available in two sizes, ordered separately) allows for the simultaneous programming and readout of up to 8 loggers, eliminating the need for an additional module.
- Specialized Software: The testo 190 CFR software (ordered separately) complies with **21 CFR Part 11** requirements.
- Software Convenience: The simple and clear software structure with notifications at critical points allows even inexperienced operators to use it without problems.
Technical Data (Order Number 0572 1900)
Absolute Pressure Measurement
| Measuring Range: | 1 mbar … 4 bar |
| Accuracy: | ±20 mbar |
| Resolution: | 1 mbar |
| Response Time: | t90 = 0.2 s. |
General Technical Data
| Dimensions: | 22 x 83 mm (diameter x height) |
| Operating Temperature: | 0 … 140 °C |
| Storage Temperature: | -20 … +50 °C |
| Housing: | Stainless steel, PEEK plastic |
| Protection Class: | IP68 |
| Battery Type: | 1/2 AA lithium |
| Battery Life: | 2,500 operating hours (10 sec cycle at +121 °C) |
| Memory: | 60,000 readings |
| Measurement Frequency: | 1 s – 24 h |
| Channels: | 1 |
| Authorizations: | CE |