Description
Instrument Overview (Order Number 0590 7601)
Ideal for measuring all important electrical parameters. Key features include automatic recognition and selection of the measuring parameter, operation via function buttons, and a large backlit display.
Application Areas Overview
- Checking for voltage supply in live conductors.
- Checking the continuity of switches.
- Measurement of the resistance of sensors or motor coils.
Technical Data (Order Number 0590 7601)
General Technical Data
| Weight: | 340 g |
| Dimensions: | 167 x 85 x 45 mm |
| Product Color: | black |
| Operating Temperature: | -10 … +50 °C |
| Storage Temperature: | -15 … +60 °C |
| Operating Humidity: | 0 … 80 % RH |
| Protection Class: | IP64 |
| Standards: | EN 61326-1; EN 61010-2-033; EN 61140 |
| Overvoltage Category: | CAT III 600V; CAT IV 300V |
| Authorizations: | CSA; CE |
| Battery Type: | 2 AAA microcells |
| Display Type: | LCD |
| Display Size: | two lines |
| Interface: | 4 measuring jacks |
| Passive Resistance (AC/DC): | 11 MΩ |
| Display (Digits): | 4 000 |
DC Voltage Measurement (DC)
| Measuring range: | 0.1 … 600 V |
| Resolution: | max. 0.1 meas. value |
| Accuracy: | ± (0.8 % of meas. value + 3 Digit) |
AC Voltage Measurement (AC)
| Measuring range: | 0.1 meas. value … 600 V |
| Resolution: | max. 0.1 meas. value |
| Accuracy: | ± (1.0 % of meas. value + 3 Digit) |
DC Current Measurement (DC Current)
| Measuring range: | 0.1 mA … 10 A |
| Resolution: | max. 0.1 |
| Accuracy: | ± (1.5 % of meas. value + 5 Digit) |
AC Current Measurement (AC Current)
| Measuring range: | 0.1 mA … 10 A |
| Resolution: | max. 0.1 mA |
| Accuracy: | ± (1.0 % of meas. value + 3 Digit) |
Resistance Measurement
| Measuring range: | 0.1 … 40.00 MΩ |
| Resolution: | max. 0.1 Ω |
| Accuracy: | ± (1.5 % of meas. value + 3 Digit) |
Capacitance Measurement
| Measuring range: | 0.001 nF … 100 µF |
| Resolution: | max. 0.01 nF |
| Accuracy: | ± (1.5 % of meas. value + 5 Digit) |
Frequency Measurement
| Measuring range: | 0.001 Hz … 512.0 kHz |
| Resolution: | max. 0.001 Hz |
| Accuracy: | ± (0.1 % of meas. value + 1 Digit) |
Measuring Instrument Functions
| Automatic parameter detection: | yes |
| Diode test: | yes |
| Continuity check: | yes |
| Display lighting: | yes |
| Hold: | yes |
| Min./Max. values: | yes |