testo 340, Flue gas analyzer for 4 measured gases

The compact form and accessible technology make the testo 340 gas analyzer ideal for operation, service, and maintenance, as well as for control measurements of industrial boilers, gas turbines, stationary industrial engines, and thermal processes.

Advantages of the testo 340 gas analyzer:

1. Maximum number of sensors: 4. The instrument is equipped with an O2 sensor as standard. You can configure 3 additional sensors yourself from a selection of: CO (with H2-compensation), CO low (with H2-compensation), NO, NO low, NO2, and SO2.

2. The gas analyzer has a built-in function for differential pressure and velocity measurement as standard.

3.The CO (with H2-compensation) and NO sensors come with replaceable filters. This filter prevents certain gases from passing through the sensor. If the filter is worn, the user can replace it independently.

4. Optimal protection safeguards the instrument against impact.

Contact by email

Description

testo 340 Flue Gas Analyzer
Calculated Parameters
  • Dew point
  • Heat loss + Efficiency (ETA)
  • CO – undiluted
  • NOx
  • Flow velocity (volume flow, mass flow)
  • Lambda (λ)
  • Gas consumption
  • Battery capacity (%)
  • Sensor diagnostics

Scope of Delivery and Registration Data
DescriptionOrder Number
testo 340 flue gas analyzer, including rechargeable battery, calibration protocol, equipped with O2

sensor and option for differential pressure and velocity measurement
0632 3400
Instrument type registration0632 3340

Registered in the Register of the State System for Ensuring the Uniformity of Measurements of the Republic of Kazakhstan

28.03.2022 with No. KZ.02.01.01474-2022 type designation

Valid until 28.03.2027


Technical Data (Measurement Ranges)
Gas Parameters
ParameterMeasurement Range
O2
0 … 25 % vol.
CO (with H2-compensation) with replaceable filter0 … 10,000 ppm
NO with replaceable filter0 … 3,000 ppm
CO
low

(with H
2-compensation)
0 … 500 ppm
NO
low
0 … 300 ppm
NO2
0 … 500 ppm
SO2
0 … 5,000 ppm
Pressure and Temperature Measurement
ParameterMeasurement RangeResolution
Pressure (Differential)

-40 … 40 hPa

-200 … 200 hPa

0.01 hPa

0.1 hPa

Temperature (NiCr-Ni)-40 °C … 1,200 °C